BIXOLON SRP-F312 Specifikace Strana 30

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 145
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 29
SRP-F310/312
Rev. 1.00 BIXOLON
- 30 -
ESC @
Function: Initialize printer
Code:
ASCII
ESC @
Hex
1B 40
Decimal
27 64
Range:
None
Default:
None
Description:
This command cancels conditions previously set and initializes the printer to the conditions having existed at power on.
Remarks:
The data in the printer buffer is cleared.
The settings of DIP switch are not re-read.
The data in the receive buffer is not discarded.
All of the settings such as print mode and line feed are cleared.
NV graphics and NV user memory are not cleared.
In page mode, this command removes the data in print areas, restores the initial settings and returns to standard
mode.
Differences:
None
Zobrazit stránku 29
1 2 ... 25 26 27 28 29 30 31 32 33 34 35 ... 144 145

Komentáře k této Příručce

Žádné komentáře