GS B
Function:
Turns white/black reverse printing mode on / off
Code:
ASCII
GS
B
n
Hex
1D
42
n
Decimal
29
66
n
Range:
0 ≤ n ≤ 255
Default:
n = 0
Description:
This command selects white/black reverse printing mode by setting the least significant bit of n.
When the LSB of n is 0, white/black reverse mode is turned off.
When the LSB of n is 1, white/black reverse mode is turned on.
Remarks:
This command does not affect multi-byte characters such as Kanji, Japanese and Korean.
The right space defined by ESC SP is affected by this command.
In white/black reverse mode, the underline mode is not effective.
This mode remains effective until ESC @, printer reset or power cycling is executed.
Differences:
None