BIXOLON SPP-R300 Specifikace Strana 51

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 149
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 50
SPP-R300 Command Manual
Rev. 1.00 BIXOLON
- 51 -
GS ( A
Function: Execute test print
Code:
ASCII
GS ( A pL pH n m
Hex
1D 28 41 pL pH n m
Decimal
29 40 65 pL pH n m
Range:
(pL + pH x 256) = 2 (pL=2, pH=0)
0 n 2, 48 n 50
1 m 3, 49 m 51
Default:
None
Description:
This command prints a specified pattern for testing on a roll paper.
Roll paper is selected with n specified as follows:
n Paper type
0, 48
1, 49
2, 50
Roll paper
Different kinds of test patterns are selected according to m as follows:
m Test pattern
1, 49 Hexadecimal dump mode
2, 50 Printer configuration printing
3, 51 Rolling pattern printing
Remarks:
The printer cancels a macro definition in progress If this command is processed. The macro becomes invalid.
After completion of this command, a software reset is executed automatically to restore the printer status set during
power cycling.
All of the data transmitted from the host to the printer is printed and identified in hexadecimal dump mode.
The real time command and ASB operations are not executed during the printing of printer configuration (m=2, 50)
and rolling pattern (m=3, 51).
Differences:
None